Flintec load cell supports are designed
to prevent unwanted forces from affecting load cell performance. The
Type 55-01-09 is a self aligning weigh module, with excellent load introduction.
The module is especially designed for using Flintec rocker column load
cells in hopper and tank weighing applications. The module incorporates
an integrated bumper stop eliminating the need of using check links
thereby offering highest possible precision. The Weigh Module will be
shipped completely pre- assembled including a dummy load cell; ready
for installation by welding. In case of horizontal forces from slow
moving agitators etc., use the check link option (Can be added afterwards,
would the need arise). Material: steel, zinc plated.